| Type | Vacuum Epoxy Cast Dry Type AC/DC Test Transformer |
|---|---|
| Function | Supports Cascade Connection |
| Output Waveform | Power Frequency Sine Wave |
| Rated Capacity | 1.5kVA~30kVA Multiple Options |
| DC Output Voltage | DC 70kV / 140kV (with HV Silicon Stack) |
| Model | HZG1501 |
|---|---|
| Insulation Medium | Pure SF6 Gas |
| Output Voltage | 50/100/150/200kV, Customizable |
| Input Voltage | AC200V(≤10kVA) / AC400V(>10kVA) |
| No-load Loss | ≤10% |
| Model Type | Oil Immersed AC/DC High Voltage Test Transformer |
|---|---|
| Rated Capacity | 1.5kVA~100kVA Multiple Ratings |
| Function Feature | Single Unit Operation & Cascade Connection Available |
| AC Output Voltage | AC 50kV / 100kV / 150kV Optional |
| DC Output Voltage | DC 70kV / 140kV / 210kV Optional |
| Model | The HZD1601 |
|---|---|
| Hv Voltage | AC DC 50kV-300kV Customizable |
| Voltage Range | Up To 1000 KV |
| Frequency | 50/60 Hz |
| Customized | Voltage Capacity Configurations Can Be Customized According To Requirements |
| Rated Powe | 120W / 180W / 300W |
|---|---|
| Overload Capacity | 1.25× Rated Current |
| Power Supply | AC 220V ±10%, 50Hz |
| Operating Mode | 30min Rated Load Intermittent Use |
| Measurement Accuracy | ±(1.0% Reading ± 2 Digits) |
| Model | TAG-8700 |
|---|---|
| Test Voltage Range | 5V ~ 220kV |
| Phase Difference Accuracy | ≤ 5° |
| Frequency Accuracy | ±0.1 Hz |
| Wireless Transmission Distance | Approx. 100m |
| Max AC/DC Voltage | 300kV |
|---|---|
| AC Accuracy | ±1.5% |
| DC Accuracy | ±1.0% |
| Voltage Dividing Ratio | 1000:1 |
| Display Resolution | 0.001kV |
| Test Range | 0.8~10000 |
|---|---|
| Testable Objects & Functions | Supports Three-phase Transformer, Single-phase Transformer, PT, CT, Z-type Transformer; Tests Transformation Ratio, Vector Group And Polarity; Supports CT Polarity Ratio Test And Single-phase Angle Difference Test |
| Alarm Function | High & Low Voltage Reverse Connection Alarm, Output Short Circuit Alarm |
| Power Supply | Built-in Lithium Battery; Adapter Input: AC 100-240V, 50/60Hz, Output: DC 15V ≥1A; 5.5*2.1mm DC Interface |
| Measurement Accuracy | ≤1000: ±(Reading×0.1%+2 Digits); 1000~3000: ±(Reading×0.2%+2 Digits); >3000: ±(Reading×0.3%+2 Digits) |
| Harmonic Output | Up To 20th Harmonic |
|---|---|
| AC Voltage Output | 4 × 120 V |
| DC Voltage Output | ±160 V Per Phase |
| Frequency Range | 0–1000 Hz |
| AC Current Output | 3 × 40 A, Max 120 A In Parallel |
| Output Channel Configuration | Standard 6 AC Current Channels + 6 AC Voltage Channels; Freely Combined Modes: 4U3I / 6U / 6I / 12-phase |
|---|---|
| AC Current Output Specifications | 1. 6-phase Separate Output: 0~30A/phase, Accuracy Class 0.2 2. 3-phase Output: 0~60A/phase 3. 6-phase Parallel Output: 0~180A 4. Continuous Allowable Current: 10A/phase 5. Max Single-phase Power: 450VA 6. Total Max Parallel Power: 1000VA 7. Duration For 18 |
| AC Voltage Output Specifications | Phase Voltage: 0~120VAC/phase, Accuracy Class 0.2 Line Voltage: 0~240VAC Power: 80VA(phase) / 100VA(line) |
| DC Current Output | Range: 0~±10A Per Phase, Accuracy Class 0.5 Max Load Voltage: 20VDC |
| Frequency & Harmonic Index | Fundamental Frequency: 0~1000Hz Superimposable Harmonics: 1~20 Orders |