| Access Status | Forbidden |
|---|---|
| Server | Openresty |
| User Permission | Insufficient |
| Authentication | Required Or Failed |
| Server Type | Web Server |
| Customized | Voltage And Capacity Configurations Can Be Customized According To The Test Object And Technical Requirements. |
|---|---|
| Type | Vacuum Epoxy Cast Dry Type AC/DC Test Transformer |
| Rated Capacity | 1.5kVA~30kVA Multiple Options |
| AC Output Voltage | AC 50kV / 100kV / 120kV Optional |
| DC Output Voltage | DC 70kV / 140kV (with HV Silicon Stack) |
| Customized | Logo · Color · Housing · Function Etc |
|---|---|
| Test Frequency | 0.1Hz (Optional 0.05Hz / 0.01Hz) |
| VLF Sine Output Voltage | VLF-34kV: 24kV RMS (34kV Peak) VLF-45kV: 31.8kV RMS (45kV Peak) |
| DC Output Voltage Range | VLF-34kV: ±1kV ~ ±34kV VLF-45kV: ±1kV ~ ±45kV |
| Tan Delta Test Voltage Range | VLF-34kV: 1kV ~ 24kV RMS VLF-45kV: 1kV ~ 31.8kV RMS |
| Customized | Voltage And Capacity Configurations Can Be Customized According To The Test Object And Technical Requirements. |
|---|---|
| Model Type | Oil Immersed AC/DC High Voltage Test Transformer |
| AC Output Voltage | AC 50kV / 100kV / 150kV Optional |
| DC Output Voltage | DC 70kV / 140kV / 210kV Optional |
| Rated Capacity | 1.5kVA~100kVA Multiple Ratings |
| Rated Test Voltage | 100V/250V/500V/1000V/2500V/5000V, Customizable |
|---|---|
| Insulation Resistance Range | 0.50MΩ ~ 2000GΩ |
| DC Voltage Test Range | 0 ~ 1000V , Customizable |
| AC Voltage Test Range | 0 ~ 750V , Customizable |
| Short Circuit Current | ≥5mA (5000V) |
| Model | HZG1701 |
|---|---|
| Waveform Distortion | ≤5% |
| Measurement Accuracy | ≤3% |
| Output Voltage | 30/40/50/60/80/90kV (Peak Value) |
| Load Capacity | 0.1Hz≤1.1μF, 0.05Hz≤2.2μF, 0.02Hz≤5.5μF |
| Highlight | On-Site Testing Electrical Testing Services,Equipment Commissioning Power Testing Services,Technical Training Testing Support Services |
|---|
| Model | HZG1501 |
|---|---|
| Insulation Medium | Pure SF6 Gas |
| Output Voltage | 50/100/150/200kV, Customizable |
| Input Voltage | AC200V(≤10kVA) / AC400V(>10kVA) |
| No-load Loss | ≤10% |
| Specification | 60kV/2mA, 60kV/3mA, 60kV/5mA |
|---|---|
| Rated Powe | 120W / 180W / 300W |
| Measurement Accuracy | ±(1.0% Reading ± 2 Digits) |
| Ripple Coefficient | ≤0.5% |
| Overload Capacity | 1.25× Rated Current |
| Customized | Logo · Color · Housing · Function Etc |
|---|---|
| Test Range | 0.8~10000 |
| Measurement Accuracy | ≤1000: ±(Reading×0.1%+2 Digits); 1000~3000: ±(Reading×0.2%+2 Digits); >3000: ±(Reading×0.3%+2 Digits) |
| Resolution | 0.9~9.9999: 0.0001; 10~99.999: 0.001; 100~999.99: 0.01; 1000~9999.9: 0.1; 10000: 1 |
| Testable Objects & Functions | Supports Three-phase Transformer, Single-phase Transformer, PT, CT, Z-type Transformer; Tests Transformation Ratio, Vector Group And Polarity; Supports CT Polarity Ratio Test And Single-phase Angle Difference Test |