products
I'm Online Chat Now
Contact Person : fiona
Phone Number : +8618071531810
WhatsApp : +8618071531810
Keywords [ cable withstand voltage tester ] match 5 Products.
VIDEO VLF Cable Tan Delta Tester with 0.1Hz VLF AC Withstand Voltage Testing and Tan Delta Measurement for 31.8kV RMS Cable Insulation Diagnosis

VLF Cable Tan Delta Tester with 0.1Hz VLF AC Withstand Voltage Testing and Tan Delta Measurement for 31.8kV RMS Cable Insulation Diagnosis

MOQ: 1
Customized Logo · Color · Housing · Function Etc
Test Frequency 0.1Hz (Optional 0.05Hz / 0.01Hz)
VLF Sine Output Voltage VLF-34kV: 24kV RMS (34kV Peak) VLF-45kV: 31.8kV RMS (45kV Peak)
DC Output Voltage Range VLF-34kV: ±1kV ~ ±34kV VLF-45kV: ±1kV ~ ±45kV
Tan Delta Test Voltage Range VLF-34kV: 1kV ~ 24kV RMS VLF-45kV: 1kV ~ 31.8kV RMS
HZG1901 High Voltage Withstand Tester with Web-Based Control for AC Withstand Testing and Insulation Safety Testing

HZG1901 High Voltage Withstand Tester with Web-Based Control for AC Withstand Testing and Insulation Safety Testing

MOQ: 1
Access Status Forbidden
Server Openresty
User Permission Insufficient
Authentication Required Or Failed
Server Type Web Server
VIDEO VLF AC Hipot Tester

VLF AC Hipot Tester

MOQ: 1
Model HZG1701
Waveform Distortion ≤5%
Measurement Accuracy ≤3%
Output Voltage 30/40/50/60/80/90kV (Peak Value)
Load Capacity 0.1Hz≤1.1μF, 0.05Hz≤2.2μF, 0.02Hz≤5.5μF
60kV Portable DC High Voltage Generator with Low Ripple for Insulation Testing

60kV Portable DC High Voltage Generator with Low Ripple for Insulation Testing

MOQ: 1
Specification 60kV/2mA, 60kV/3mA, 60kV/5mA
Rated Powe 120W / 180W / 300W
Measurement Accuracy ±(1.0% Reading ± 2 Digits)
Ripple Coefficient ≤0.5%
Overload Capacity 1.25× Rated Current
Six Phase Relay Protection Test Set for Power System Testing

Six Phase Relay Protection Test Set for Power System Testing

MOQ: 1
Output Channel Configuration Standard 6 AC Current Channels + 6 AC Voltage Channels; Freely Combined Modes: 4U3I / 6U / 6I / 12-phase
AC Current Output Specifications 1. 6-phase Separate Output: 0~30A/phase, Accuracy Class 0.2 2. 3-phase Output: 0~60A/phase 3. 6-phase Parallel Output: 0~180A 4. Continuous Allowable Current: 10A/phase 5. Max Single-phase Power: 450VA 6. Total Max Parallel Power: 1000VA 7. Duration For 18
AC Voltage Output Specifications Phase Voltage: 0~120VAC/phase, Accuracy Class 0.2 Line Voltage: 0~240VAC Power: 80VA(phase) / 100VA(line)
DC Current Output Range: 0~±10A Per Phase, Accuracy Class 0.5 Max Load Voltage: 20VDC
Frequency & Harmonic Index Fundamental Frequency: 0~1000Hz Superimposable Harmonics: 1~20 Orders
Total 1 page