products
I'm Online Chat Now
Contact Person : fiona
Phone Number : +8618071531810
WhatsApp : +8618071531810
Keywords [ dry type high voltage test transformer ] match 8 Products.
Dry Type High Voltage Test Transformer for AC & DC Testing

Dry Type High Voltage Test Transformer for AC & DC Testing

MOQ: 1
Type Vacuum Epoxy Cast Dry Type AC/DC Test Transformer
Function Supports Cascade Connection
Output Waveform Power Frequency Sine Wave
Rated Capacity 1.5kVA~30kVA Multiple Options
DC Output Voltage DC 70kV / 140kV (with HV Silicon Stack)
SF6 Gas Insulated High Voltage Test Transformer with Pure SF6 Gas Insulation, Customizable Output Voltage, and Compact Lightweight Design

SF6 Gas Insulated High Voltage Test Transformer with Pure SF6 Gas Insulation, Customizable Output Voltage, and Compact Lightweight Design

MOQ: 1
Model HZG1501
Insulation Medium Pure SF6 Gas
Output Voltage 50/100/150/200kV, Customizable
Input Voltage AC200V(≤10kVA) / AC400V(>10kVA)
No-load Loss ≤10%
VIDEO Ultra-Light AC/DC Test Transformer for Withstand Testing

Ultra-Light AC/DC Test Transformer for Withstand Testing

MOQ: 1
Model Type Oil Immersed AC/DC High Voltage Test Transformer
Rated Capacity 1.5kVA~100kVA Multiple Ratings
Function Feature Single Unit Operation & Cascade Connection Available
AC Output Voltage AC 50kV / 100kV / 150kV Optional
DC Output Voltage DC 70kV / 140kV / 210kV Optional
VIDEO AC/DC Withstand Voltage Test Equipment for High Voltage Testing

AC/DC Withstand Voltage Test Equipment for High Voltage Testing

MOQ: 1
Model The HZD1601
Hv Voltage AC DC 50kV-300kV Customizable
Voltage Range Up To 1000 KV
Frequency 50/60 Hz
Customized Voltage Capacity Configurations Can Be Customized According To Requirements
HZG1301 Triple Frequency Induced Withstand Voltage Device

HZG1301 Triple Frequency Induced Withstand Voltage Device

MOQ: 1
Highlight

150Hz Output Frequency Triple Frequency Induced Withstand Voltage Device

,

Integrated Design High Voltage Test Equipment

,

Overcurrent Protection Triple Frequency Generator

Delivery Time 5-8 workdays
Supply Ability 1000
Insulating Clothing Test Device

Insulating Clothing Test Device

MOQ: 1
Highlight

50kV Test Transformer Insulating Clothing Test Device

,

Compliant with IEC903:1988 Insulating Garment Test Bench

,

Integrated Platform Layout High Voltage Test Equipment

Delivery Time 5-8 workdays
Supply Ability 1000
300kV AC/DC High Voltage Divider

300kV AC/DC High Voltage Divider

MOQ: 1
Max AC/DC Voltage 300kV
AC Accuracy ±1.5%
DC Accuracy ±1.0%
Voltage Dividing Ratio 1000:1
Display Resolution 0.001kV
Six Phase Relay Protection Test Set for Power System Testing

Six Phase Relay Protection Test Set for Power System Testing

MOQ: 1
Output Channel Configuration Standard 6 AC Current Channels + 6 AC Voltage Channels; Freely Combined Modes: 4U3I / 6U / 6I / 12-phase
AC Current Output Specifications 1. 6-phase Separate Output: 0~30A/phase, Accuracy Class 0.2 2. 3-phase Output: 0~60A/phase 3. 6-phase Parallel Output: 0~180A 4. Continuous Allowable Current: 10A/phase 5. Max Single-phase Power: 450VA 6. Total Max Parallel Power: 1000VA 7. Duration For 18
AC Voltage Output Specifications Phase Voltage: 0~120VAC/phase, Accuracy Class 0.2 Line Voltage: 0~240VAC Power: 80VA(phase) / 100VA(line)
DC Current Output Range: 0~±10A Per Phase, Accuracy Class 0.5 Max Load Voltage: 20VDC
Frequency & Harmonic Index Fundamental Frequency: 0~1000Hz Superimposable Harmonics: 1~20 Orders
Total 1 page