| Highlight | Wireless power quality analyzer,Three-phase power analyzer,Power quality testing equipment |
|---|---|
| Packaging Details | 112cm (length) × 26cm (width) × 11cm |
| Delivery Time | 5-8 work days |
| Supply Ability | 10000 |
| Place of Origin | WuHan |
| Model | The HZD1601 |
|---|---|
| Hv Voltage | AC DC 50kV-300kV Customizable |
| Voltage Range | Up To 1000 KV |
| Frequency | 50/60 Hz |
| Customized | Voltage Capacity Configurations Can Be Customized According To Requirements |
| System Measurement Accuracy | 1.5% |
|---|---|
| Output Waveform Distortion | <0.01 |
| Customized | Voltage And Capacity Configurations Can Be Customized According To The Test Object And Technical Requirements. |
| Model | HZG1101 |
| Frequency Adjustment Range | 20Hz–300Hz |
| Access Status | Forbidden |
|---|---|
| Server | Openresty |
| User Permission | Insufficient |
| Authentication | Required Or Failed |
| Server Type | Web Server |
| Ratio Measurement Accuracy | ≤200: ±(Reading×0.1%+2 Digits)200~500: ±(Reading×0.2%+2 Digits)>500: ±(Reading×0.3%+2 Digits) |
|---|---|
| Ratio Resolution | 0.9~9.9999: 0.000110~99.999: 0.001100~999.99: 0.011000~1999.9: 0.1Above 2000: 0.1 |
| Max Tap Position | Maximum 99 Tap Positions |
| Power Supply | Built-in Lithium Battery With Dedicated Charging Adapter |
| Intelligent Protection & Prompt | High/low Voltage Reverse Connection & Output Short Circuit Alarm; Automatic Stop, Discharge And Wiring Removal Prompt For DC Resistance Test |
| Model | HZD1202 |
|---|---|
| Output Voltage | Approx. 400V DC |
| Test Range | 0 ~ 500Ω |
| Core Function | GPS Time Synchronization Supported |
| Full Set Configuration | Transmitter, Receiver, Test Leads, Flexible Coil |
| Model | HZG1501 |
|---|---|
| Insulation Medium | Pure SF6 Gas |
| Output Voltage | 50/100/150/200kV, Customizable |
| Input Voltage | AC200V(≤10kVA) / AC400V(>10kVA) |
| No-load Loss | ≤10% |
| Highlight | 150Hz Output Frequency Triple Frequency Induced Withstand Voltage Device,Integrated Design High Voltage Test Equipment,Overcurrent Protection Triple Frequency Generator |
|---|---|
| Delivery Time | 5-8 workdays |
| Supply Ability | 1000 |
| Rated Powe | 120W / 180W / 300W |
|---|---|
| Overload Capacity | 1.25× Rated Current |
| Power Supply | AC 220V ±10%, 50Hz |
| Operating Mode | 30min Rated Load Intermittent Use |
| Measurement Accuracy | ±(1.0% Reading ± 2 Digits) |
| Test Frequency | 0.1Hz (Optional 0.05Hz / 0.01Hz) |
|---|---|
| Tan Delta Test Voltage Range | VLF-34kV: 1kV ~ 24kV RMS VLF-45kV: 1kV ~ 31.8kV RMS |
| Max. Cable Capacitance (0.1Hz) | VLF-34kV: 0.5μF @24kVrms VLF-45kV: 0.5μF @31.8kVrms |
| VLF Sine Output Voltage | VLF-34kV: 24kV RMS (34kV Peak) VLF-45kV: 31.8kV RMS (45kV Peak) |
| DC Output Voltage Range | VLF-34kV: ±1kV ~ ±34kV VLF-45kV: ±1kV ~ ±45kV |