| Specification | 60kV/2mA, 60kV/3mA, 60kV/5mA |
|---|---|
| Rated Powe | 120W / 180W / 300W |
| Measurement Accuracy | ±(1.0% Reading ± 2 Digits) |
| Ripple Coefficient | ≤0.5% |
| Overload Capacity | 1.25× Rated Current |
| Model | HZG1501 |
|---|---|
| Insulation Medium | Pure SF6 Gas |
| Output Voltage | 50/100/150/200kV, Customizable |
| Input Voltage | AC200V(≤10kVA) / AC400V(>10kVA) |
| No-load Loss | ≤10% |
| AC Current Output | 3 × 40 A, Max 120 A In Parallel |
|---|---|
| AC Voltage Output | 4 × 120 V |
| Accuracy | Current & Voltage: 0.2% |
| DC Current Output | ±10 A Per Phase |
| DC Voltage Output | ±160 V Per Phase |
| Customized | Logo · Color · Housing · Function Etc |
|---|---|
| Test Frequency | 0.1Hz (Optional 0.05Hz / 0.01Hz) |
| VLF Sine Output Voltage | VLF-34kV: 24kV RMS (34kV Peak) VLF-45kV: 31.8kV RMS (45kV Peak) |
| DC Output Voltage Range | VLF-34kV: ±1kV ~ ±34kV VLF-45kV: ±1kV ~ ±45kV |
| Tan Delta Test Voltage Range | VLF-34kV: 1kV ~ 24kV RMS VLF-45kV: 1kV ~ 31.8kV RMS |
| Rated Test Voltage | 100V/250V/500V/1000V/2500V/5000V, Customizable |
|---|---|
| Insulation Resistance Range | 0.50MΩ ~ 2000GΩ |
| DC Voltage Test Range | 0 ~ 1000V , Customizable |
| AC Voltage Test Range | 0 ~ 750V , Customizable |
| Short Circuit Current | ≥5mA (5000V) |
| Output Channel Configuration | Standard 6 AC Current Channels + 6 AC Voltage Channels; Freely Combined Modes: 4U3I / 6U / 6I / 12-phase |
|---|---|
| AC Current Output Specifications | 1. 6-phase Separate Output: 0~30A/phase, Accuracy Class 0.2 2. 3-phase Output: 0~60A/phase 3. 6-phase Parallel Output: 0~180A 4. Continuous Allowable Current: 10A/phase 5. Max Single-phase Power: 450VA 6. Total Max Parallel Power: 1000VA 7. Duration For 18 |
| AC Voltage Output Specifications | Phase Voltage: 0~120VAC/phase, Accuracy Class 0.2 Line Voltage: 0~240VAC Power: 80VA(phase) / 100VA(line) |
| DC Current Output | Range: 0~±10A Per Phase, Accuracy Class 0.5 Max Load Voltage: 20VDC |
| Frequency & Harmonic Index | Fundamental Frequency: 0~1000Hz Superimposable Harmonics: 1~20 Orders |
| Accuracy Class | 0.2 Class |
|---|---|
| AC Phase Current Output | 0–40A, 3-phase Parallel Max 120A |
| AC Voltage Output | 0–120V Per Phase, Line Voltage 0–240V |
| Frequency Range | 0–1000Hz, Support 0–20 Times Harmonics |
| Switch Channels | 8 Input Channels, 4 Output Pairs |
| Output Current | 30A, 50A, 80A, 100A 200A Optional Gears |
|---|---|
| Measurement Resolution | 0.01μΩ |
| Test Duration | 1s / 5s / 10s / 30s / 60s Adjustable |
| Model | HZ-SHL |
| Measurement Accuracy | ±0.5% ±1μΩ |