The HZG1401 Dry Type High Voltage Test Transformer is designed for high-voltage insulation testing of electrical equipment in power systems, substations, laboratories and field applications.
Using epoxy vacuum casting technology and a dry-type insulation structure, the transformer is lighter and more compact than conventional oil-immersed test transformers. It offers convenient transportation, stable operation and no risk of oil leakage.
The HZG1401 can be used for AC withstand voltage testing, and can also be configured with high-voltage rectifier and microammeter accessories for DC withstand and leakage current testing.
Different voltage and capacity configurations are available, with OEM and ODM customization according to customer requirements.
The HZG1401 is suitable for high-voltage testing of:
Power transformers
Switchgear
Circuit breakers
Power cables
Insulators
Bushings
Electrical components
Other high-voltage electrical equipment
Used with a suitable control unit to apply power-frequency AC high voltage for insulation and dielectric withstand testing.
With optional high-voltage rectifier and digital microammeter, the system can be configured for DC withstand and leakage current testing.
The lightweight dry-type structure makes the transformer suitable for on-site testing, maintenance and commissioning.
Suitable for insulation performance testing and routine high-voltage testing during equipment manufacturing and laboratory evaluation.
| Parameter | Specification |
|---|---|
| Output Waveform | Power-frequency sine wave |
| Rated Capacity | 1.5–30 kVA |
| AC Output Voltage | 50–120 kV |
| DC Output Voltage | Up to 140 kV for applicable configurations |
| Output Current | Up to 600 mA |
| Input Voltage | 200 V or 400 V |
| Structure | Dry type, epoxy vacuum cast |
| Operation | Intermittent |
| Model | Capacity | Input | AC Output | DC Output | Current |
|---|---|---|---|---|---|
| 1.5/50 | 1.5 kVA | 200 V | 50 kV | 70 kV | 30 mA |
| 3/50 | 3 kVA | 200 V | 50 kV | 70 kV | 60 mA |
| 5/50 | 5 kVA | 200 V | 50 kV | 70 kV | 100 mA |
| 10/50 | 10 kVA | 200 V | 50 kV | 70 kV | 200 mA |
| 20/50 | 20 kVA | 200 V | 50 kV | 70 kV | 400 mA |
| 30/50 | 30 kVA | 400 V | 50 kV | 70 kV | 600 mA |
| 5/100 | 5 kVA | 200 V | 100 kV | 140 kV | 50 mA |
| 10/100 | 10 kVA | 200 V | 100 kV | 140 kV | 100 mA |
| 20/100 | 20 kVA | 200 V | 100 kV | 140 kV | 200 mA |
| 25/100 | 25 kVA | 400 V | 100 kV | 140 kV | 250 mA |
| 15/120 | 15 kVA | 400 V | 120 kV | — | 125 mA |
| 20/120 | 20 kVA | 400 V | 120 kV | — | 160 mA |
| 25/120 | 25 kVA | 400 V | 120 kV | — | 200 mA |
| 30/120 | 30 kVA | 400 V | 120 kV | — | 250 mA |
Note: The above are typical configurations. Other voltage, capacity and structural configurations can be customized according to the customer's test requirements.
Need a Different Voltage or Capacity? Contact Our Engineers
Compared with oil-immersed test transformers of similar voltage and capacity, the dry-type design offers reduced weight and smaller size for easier transportation and field operation.
The epoxy vacuum casting structure provides reliable insulation and good moisture resistance for demanding testing environments.
The dry-type design eliminates the need for insulating oil, reducing maintenance requirements and avoiding oil leakage during transportation and operation.
The transformer provides a power-frequency sinusoidal high-voltage output for AC withstand testing.
The transformer can be used for AC testing and configured with optional rectifier and microammeter accessories for DC testing.
Multiple voltage and capacity configurations are available to meet different testing requirements.
Voltage, capacity, structure and supporting accessories can be customized according to the customer's test object and project requirements.Learn more about our OEM/ODM customization →
The HZG1401 can be supplied as a standalone high-voltage test transformer or as part of a complete test system.
Generates the required high-voltage output for insulation and withstand testing.
A matching control box or control console can be supplied for voltage regulation and test operation.
Depending on the testing application, the system can include:
Capacitive voltage divider
Protective spark gap
Discharge rod
High-voltage rectifier
Digital microammeter
High-voltage connection cables
Other customized accessories
For applications requiring higher test voltage, cascade connection configurations are also available.
The correct HZG1401 configuration mainly depends on:
1.What are you testing?
For example:
Transformer / Switchgear / Cable / Insulator / Circuit Breaker / Other Electrical Equipment
2.What test voltage is required?
Please provide the required AC or DC test voltage according to your applicable testing standard.
3.What test current or capacity is required?
The transformer capacity should be selected according to the test voltage and required test current.
4.Do you need AC or DC testing?
AC testing: Dry-type test transformer
DC testing: Test transformer + high-voltage rectifier + microammeter
AC + DC: Complete AC/DC testing configuration
If you are unsure about the required capacity, simply send us the test object and required test voltage. Our engineers can recommend the appropriate configuration.
Get a Configuration Recommendation
Compared with traditional oil-immersed test transformers, the dry-type structure is easier to transport and operate on site.
Manufactured by Wuhan Hongzhi Gaocetest Electrical Technology Co., Ltd., with more than 16 years of experience in electrical testing equipment.
The transformer can be supplied individually or integrated with a control unit, voltage divider, rectifier and other accessories.
We support customized voltage, capacity, structure and complete testing configurations according to project requirements.
Each transformer is inspected and tested before shipment to verify key electrical performance and safety functions.
Our engineers provide support for equipment selection, configuration and application requirements.
It is a high-voltage transformer designed for dielectric withstand and insulation testing without using insulating oil. The HZG1401 uses an epoxy vacuum-cast dry-type structure.
It can be used for AC withstand testing of transformers, cables, switchgear, insulators and other high-voltage electrical equipment.
Yes. With a suitable high-voltage rectifier and digital microammeter, the transformer can be configured for DC withstand and leakage current testing.
Yes. The HZG1401 is a dry-type transformer and does not require insulating oil.
Yes. OEM and ODM customization are available, including output voltage, capacity, structure and accessories.
Yes. Cascade configurations can be provided for applications requiring higher test voltage. The configuration must be designed according to the required voltage and capacity.
Please provide:
Test object
Required AC/DC test voltage
Required test current or capacity, if known
AC, DC or AC/DC testing
Test location
Available power supply
Need a dry type high voltage test transformer for your electrical testing project?
Please send us:
Test Object:
Required Test Voltage:
AC / DC / AC+DC:
Required Capacity:
Test Location:
Available Power Supply:
Our engineers will recommend the appropriate transformer and supporting accessories for your application.
OEM & ODM customization available.
Email: fionahuang60@gmail.com
WhatsApp: +86 18071531810
Website: www.hkvtest.com
Wuhan Hongzhi Gaocetest Electrical Technology Co., Ltd. (HKVTEST) is a professional manufacturer of electrical and power testing equipment with 16+ years of manufacturing experience.
We provide high-voltage testing equipment and customized testing solutions for power utilities, substations, electrical equipment manufacturers, laboratories, contractors and maintenance teams.
Our products support OEM and ODM customization, with technical support covering equipment selection, configuration, manufacturing and testing.